Description: Fills missing energy hour slots in the latest target record with hourly averages read from configured Aspen Witten tags.
Calling convention: Aspen_Witten_Energy("TargetObject": String, "InterfaceObjectName": String, "HourSlotsID": String)
Parameters:
TargetObject: target CIP object name.
InterfaceObjectName: accepted by the contract but not used by the implementation.
HourSlotsID: non-empty identifier such as TRO or ENV used by GetStunde2Read.
Returns: NULL; the routine updates the latest record and does not assign a success value.
Availability: Default; Witten energy-specific and dependent on AspenWitten plus OEE_UpdateScheduler_Info mappings.
Example:
Aspen_Witten_Energy("EnergyDaily", "EnergyInterface", "ENV");