Description: Ensures that the current interface record's AspenTag_Name exists in OEE_LastValueOnTag and inserts it with the configured new-record flag and object name when missing.
Calling convention: Aspen_Witten_CheckTagPresent()
Parameters:
None; values are read from AspenTag_Name, OEE_ASPEN_Interface_NewRecord and Object_Name in the current record.
Returns: Undefined; the routine may insert a row but assigns no result.
Availability: Default; Witten-specific and requires the expected current interface object, entries and DBForm.
Example:
Aspen_Witten_CheckTagPresent();