Description: Imports Rheimmuenster IP21 values into Hour1 through Hour24 of an existing CIP object and recalculates affected records.
Calling convention: SU_RHM_GetCURData_from_IP21(ObjectName, StartTime, EndTime): Integer
Parameters:
ObjectName: configured target object.
StartTime: optional date/time string; YESTERDAY is accepted in the two-argument form.
EndTime: optional date/time string.
Returns: NULL in the current implementation, despite the registered Integer return type.
Availability: Default; Rheimmuenster site-specific and requires the fixed AspenRheimmuenster connection and scheduler mappings.
Example:
SU_RHM_GetCURData_from_IP21("RHM_Daily", "2026-08-19", "2026-08-19");