Description: Imports configured Aspen IP.21 historian tags into a continuous HP object. Depending on each interface row it may create records, update timestamp entries or BDP data, calculate 12 shift-relative hourly values and recalculate affected records.
Calling convention: OEE_HP_GetCURData_from_Historian4kontiNew("ObjectName": String, "AspenInterfaceObjectName": String, ["StartTime": TDateTime = Today], ["EndTime": TDateTime = Today]): NULL
Parameters:
ObjectName: exact target object name.
AspenInterfaceObjectName: object containing the IP21 tag-to-object mappings.
StartTime: optional numeric Delphi date/time; defaults to today.
EndTime: optional numeric Delphi date/time; defaults to today.
Returns: Always Variant NULL, although the registration text advertises Float. Import status is represented only by database changes, messages or exceptions.
Availability: Default. Requires an interactive Windows session, the AspenHPMonomers connection, the HP interface schema, a shift model and write access.
Example:
OEE_HP_GetCURData_from_Historian4kontiNew("HP_Konti", "AspenInterface", StartDate, EndDate);