Description: Checks whether the summed durations of an extruder record's downtime rows equal the record's total time-loss entry within one second.
Calling convention: CIP_HP_CheckCurrendRecord4Downtimes(ObjectName, DataID)
Parameters:
ObjectName: registered master object name.
DataID: master record DATA_ID.
Returns: Boolean TRUE when both sums are equal within one second, FALSE when they differ, or NULL for invalid inputs or object names.
Availability: Default registration, but specific to the HP downtime schema and DATA_DOWNTIMES_EXTRUDER.
Example:
IsConsistent := CIP_HP_CheckCurrendRecord4Downtimes("ExtruderShift", DataID);